Ultraviolet filter unit
installed in gravity return line
of non pressurized biological filter
Ultraviolet filter installed in the gravity return
line of an open bed,
non pressurized, gravity return feed type biological filter.
Electrical and uv bulb access is located on right
of ultraviolet filter unit.
The ultraviolet unit ports are oriented
downward to prevent fine sediment from collection in the
chamber of the unit.
The ultraviolet unit is located lower
than the exit port of the biological filter. This provides a
flooded or near-flooded chamber in the unit.
It doesn't make any difference
which end of the ultraviolet unit the water enters or exits.
The ultraviolet
unit can be placed a further distance from the biological filter
as long as it is mounted as show above & is lower than
the output port of the biological filter.
Mounting the ultraviolet
filter on the return side of any biological filter creates
a minimum maintenance setup & reduces the collection
of bacterial or organic mulm in the ultraviolet filter.
We recommend glueing short lengths
(5" to 6" long, minimum) into each port of the UV unit
before glueing any fittings, unions, or reducer bushings. This
allows for the option of relocating the unit at a later date,
if needed. We do not recommend ever glueing a reducer bushing
directly into the entrance or exit ports of the UV unit.